Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LA 205-S/SP33SENSORS |
0 |
|
Datasheet |
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.6% | ±15V | 500ns | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SP28TRANSDUCER |
0 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | 0.2mA/A | 150kHz | ±0.1% | ±0.3% | 14.25V ~ 25.2V | 500ns | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SPA1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ENCORE (4A)TRANSDUCER CURRENT SENS SHUNT 4A |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -25°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (5A)TRANSDUCER CURRENT SENS SHUNT 5A |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 5A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | 8ns | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (500MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 500mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (4A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (1MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 1mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (300MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 300mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (2A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 2A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (2MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 2mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (3A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (200MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 200mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (3MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (5A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 50A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
DK 300 B10TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DK 400 B10TRANSDUCER |
0 |
|
- |
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 50V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 200 B10TRANSDUCER |
0 |
|
Datasheet |
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 100A, 150A, 200A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 400 B5TRANSDUCER |
0 |
|
- |
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Analog Voltage | - | DC | ±0.75% | ±2% | 20V ~ 50V | 300ms | 100mA | -20°C ~ 50°C | - | - | - | Chassis Mount | - |
|
CTSS0000SENSOR CURRENT SWITCH 150A AC |
0 |
|
Datasheet |
CTS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 150A | 1 | SSR | - | 6Hz ~ 100Hz | - | - | Self Powered | 120ms | 150mA | -50°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
Current Sensors Electronic Components