| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AHR 1500 B10TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 2000 B5TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
LF 2010-S/SPA0TRANSDUCER |
0 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | 0.2mA/A | 150kHz | ±0.1% | ±0.3% | 14.25V ~ 25.2V | 500ns | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
PCM 10-PR/SP1TRANSDUCER |
0 |
|
- |
PCM | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 10A | 1 | Current | - | DC, 40Hz ~ 1kHz | - | ±2% | 24V | - | - | -25°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
DHR 200 C10/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 600-TFTRANSDUCER |
0 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.7% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR5220S-200SENSOR CURRENT HALL 200A DC |
0 |
|
Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 50mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
LV 100/SP48SENSORS |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-S/SP2TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 1005-S/SP32TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-S/SP5TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 720A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±24V | 1µs | - | -40°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 1005-S/SP26TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 1500-SBTRANSDUCER |
0 |
|
Datasheet |
HOP | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 4000-SBI/SP1TRANSDUCER |
0 |
|
Datasheet |
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 4000A | 1 | Current | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 4000-SBTRANSDUCER |
0 |
|
Datasheet |
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 4000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 100-STRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AKR 5 C420LTRANSDUCER |
0 |
|
- |
AKR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Analog Voltage | - | 10Hz ~ 400Hz | - | ±1% | 24V | 600ms | - | -20°C ~ 50°C | - | - | - | Chassis Mount | - |
|
IVT-S-100-U3-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
Datasheet |
IVT-S | Module | Tray | Active | DC | Shunt | 100A | 3 | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
PCM 20-PTRANSDUCER |
0 |
|
- |
PCM | Module, Single Pass Through | Bulk | Not For New Designs | DC | Hall Effect, Closed Loop | 20A | 1 | Current | - | DC ~ 1kHz | ±0.2% | ±1% | ±24V | 5µs | 55mA | -25°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL0501FSENSOR CURRENT XFMR 10A, 20, 50A |
0 |
|
Datasheet |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A, 20, 50A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 60Hz | - | ±1% | Self Powered | 100ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
Current Sensors Electronic Components