Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
20310509101SENSOR CURRENT HALL 500A AC |
0 |
|
Datasheet |
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±1% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-2K5-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
Datasheet |
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-TTRANSDUCER |
0 |
|
Datasheet |
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL2001FSENSOR CURRENT 100A, 150A, 200A |
0 |
|
Datasheet |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 60Hz | - | ±1% | Self Powered | 100ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
AK 5 B420LTRANSDUCER |
0 |
|
- |
AK | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Current | - | 20Hz ~ 100Hz | - | ±1% | 24V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNM191-005SENSOR CURRENT HALL 1000A AC/DC |
0 |
|
Datasheet |
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 1µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 10-I/SP8SENSORS |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4150-75SENSOR CURRENT XFMR 75A AC |
0 |
|
Datasheet |
CR4100 | Module, Dual Pass Through | Bulk | Obsolete | AC | Transformer w/Conditioning | 75A | 2 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 75mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LT 1005-S/SP3TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-S/SP3TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD4110-25SENSOR CURRENT XFMR 25A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-15SENSOR CURRENT XFMR 15A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-5SENSOR CURRENT XFMR 5A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-1SENSOR CURRENT XFMR 1A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
PCM 30-PTRANSDUCER |
0 |
|
- |
PCM | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 30A | 1 | Current | - | DC ~ 1kHz | ±0.2% | ±1% | 24V | 30µs | 50mA | -25°C ~ 55°C | - | - | Unidirectional | Through Hole | - |
|
AHR 1000 B5TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1000 B10TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 2000 B10TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1500 B420TRANSDUCER |
0 |
|
Datasheet |
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.