Hello! Welcome to Raywise Technologies Co.,Limited!

Gas Sensors

Photo Mfr. Part # Availability Quantity Datasheet Series Packaging Product Status Type Oxygen Range Accuracy Output Operating Temperature Voltage - Supply Current - Supply
T5100-E-V Amphenol Advanced Sensors (Telaire) electronic component

T5100-E-V

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

4
RFQ

Datasheet

T5100 Bulk Active Carbon Dioxide (CO2) - ±3% 0V ~ 5V, 0V ~ 10V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
T5100-E-GN-V Amphenol Advanced Sensors (Telaire) electronic component

T5100-E-GN-V

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

4
RFQ

Datasheet

T5100 Bulk Active Carbon Dioxide (CO2) - ±3% 0V ~ 5V, 0V ~ 10V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
T5100-GN-V Amphenol Advanced Sensors (Telaire) electronic component

T5100-GN-V

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

4
RFQ

Datasheet

T5100 Bulk Active Carbon Dioxide (CO2) - ±3% 0V ~ 5V, 0V ~ 10V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
IR11EJ Amphenol SGX Sensortech electronic component

IR11EJ

SENSOR CARBON DIOXIDE VOLT OUT

Amphenol SGX Sensortech

4
RFQ

Datasheet

IR1 Bulk Active Carbon Dioxide (CO2) - - Voltage -20°C ~ 55°C 3V ~ 5V 35mA
IR12EM Amphenol SGX Sensortech electronic component

IR12EM

SENSOR HYDROCARBON VOLTAGE OUT

Amphenol SGX Sensortech

2
RFQ

Datasheet

IR1 Bulk Active Hydrocarbons, Methane - - Voltage -20°C ~ 55°C 3V ~ 5V 35mA
IR12GM_1 Amphenol SGX Sensortech electronic component

IR12GM_1

SENSOR HYDROCARBON VOLTAGE OUT

Amphenol SGX Sensortech

6
RFQ

Datasheet

IR1 Bulk Active Hydrocarbons, Methane - - Voltage -20°C ~ 55°C 3V ~ 5V -
INIR2-RF-R290 Amphenol SGX Sensortech electronic component

INIR2-RF-R290

SENSOR INTEG INFRARED

Amphenol SGX Sensortech

15
RFQ

-

* Bulk Active - - - - - - -
VQ622T/1 Amphenol SGX Sensortech electronic component

VQ622T/1

SENSOR HYDROCARBONS VOLTAGE OUT

Amphenol SGX Sensortech

16
RFQ

Datasheet

VQ600 Bulk Active Hydrocarbons - - Voltage -20°C ~ 60°C 2V 175mA
VQ621T/1 Amphenol SGX Sensortech electronic component

VQ621T/1

SENSOR HYDROCARBONS VOLTAGE OUT

Amphenol SGX Sensortech

13
RFQ

Datasheet

VQ600 Bulk Active Hydrocarbons - - Voltage -20°C ~ 60°C 2V 300mA
IR21EJ Amphenol SGX Sensortech electronic component

IR21EJ

SENSOR CARBON DIOXIDE VOLT OUT

Amphenol SGX Sensortech

22
RFQ

Datasheet

IR2 Bulk Active Carbon Dioxide (CO2) - ±0.5% Voltage -20°C ~ 60°C 3V ~ 5V 60mA
IR11GM Amphenol SGX Sensortech electronic component

IR11GM

SENSOR CARBON DIOXIDE VOLT OUT

Amphenol SGX Sensortech

13
RFQ

Datasheet

IR1 Bulk Active Carbon Dioxide (CO2) - - Voltage -20°C ~ 55°C 3V ~ 5V 60mA
VQ641TS/1 Amphenol SGX Sensortech electronic component

VQ641TS/1

SENSOR HYDROCARBONS VOLTAGE OUT

Amphenol SGX Sensortech

11
RFQ

Datasheet

VQ600 Bulk Active Hydrocarbons - - Voltage -20°C ~ 60°C 2V 100mA
T8041-5V Amphenol Advanced Sensors (Telaire) electronic component

T8041-5V

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

5
RFQ

Datasheet

Ventostat® Bulk Active Carbon Dioxide (CO2) - - 0V ~ 5V, 0V ~ 10V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
INIR-PR2.1% Amphenol SGX Sensortech electronic component

INIR-PR2.1%

SENSOR AIR QUALITY VOLTAGE OUT

Amphenol SGX Sensortech

13
RFQ

Datasheet

- Bulk Active Air Quality - - Voltage -40°C ~ 75°C 3.2V ~ 5.25V 35mA
PS1-CO-10-MOD Amphenol SGX Sensortech electronic component

PS1-CO-10-MOD

SENSOR CARBON MONOXIDE UART OUT

Amphenol SGX Sensortech

16
RFQ

Datasheet

PS1 Bulk Active Carbon Monoxide (CO) - ±5% UART -40°C ~ 55°C 3.3V ~ 5.5V 5mA
IR12GM Amphenol SGX Sensortech electronic component

IR12GM

SENSOR METHANE VOLTAGE OUTPUT

Amphenol SGX Sensortech

3
RFQ

Datasheet

IR1 Bulk Active Methane - - Voltage -20°C ~ 55°C 3V ~ 5V 60mA
T5100-LED Amphenol Advanced Sensors (Telaire) electronic component

T5100-LED

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

7
RFQ

Datasheet

T5100 Bulk Active Carbon Dioxide (CO2) - ±2% 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
IR12BD Amphenol SGX Sensortech electronic component

IR12BD

SENSOR METHANE VOLTAGE OUTPUT

Amphenol SGX Sensortech

21
RFQ

Datasheet

IR1 Bulk Active Methane - - Voltage -20°C ~ 55°C 3V ~ 5V 60mA
IR22BD Amphenol SGX Sensortech electronic component

IR22BD

SENSOR METHANE VOLTAGE OUTPUT

Amphenol SGX Sensortech

6
RFQ

Datasheet

IR2 Bulk Active Methane - - Voltage -20°C ~ 60°C 3V ~ 5V 60mA
IR13BD Amphenol SGX Sensortech electronic component

IR13BD

SENSOR METHANE VOLTAGE OUTPUT

Amphenol SGX Sensortech

12
RFQ

Datasheet

IR1 Bulk Active Methane - - Voltage -20°C ~ 55°C 3V ~ 5V 60mA
Total 1306 Record«Prev1... 910111213141516...66Next»

Gas Sensors Electronic Components

Explore Gas Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.

Frequently Asked Questions