Hello! Welcome to Raywise Technologies Co.,Limited!

Gas Sensors

Photo Mfr. Part # Availability Quantity Datasheet Series Packaging Product Status Type Oxygen Range Accuracy Output Operating Temperature Voltage - Supply Current - Supply
T8100-5V Amphenol Advanced Sensors (Telaire) electronic component

T8100-5V

SENSOR CARBON DIOXIDE 0-5V OUT

Amphenol Advanced Sensors (Telaire)

9
RFQ

Datasheet

T8000 Bulk Active Carbon Dioxide (CO2), Humidity, Temperature - ±2% 0 V ~ 5 V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
SGX-HCL-30 Amphenol SGX Sensortech electronic component

SGX-HCL-30

SENSOR HYDROGEN CHLORIDE

Amphenol SGX Sensortech

9
RFQ

-

SGX Bulk Active Hydrogen Chloride (HCl) - - - -20°C ~ 40°C - -
SGX-F2-5 Amphenol SGX Sensortech electronic component

SGX-F2-5

SENSOR FLUORINE 5PPM

Amphenol SGX Sensortech

9
RFQ

Datasheet

SGX Bulk Active Fluorine (F) - - - -20°C ~ 40°C - -
T3031-2-10K-24-P Amphenol Advanced Sensors (Telaire) electronic component

T3031-2-10K-24-P

SENSOR CARBON DIOXIDE 0-10V OUT

Amphenol Advanced Sensors (Telaire)

4
RFQ

Datasheet

T3000 Bulk Active Carbon Dioxide (CO2) - ±5% 0 V ~ 10 V 0°C ~ 50°C 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC -
T8200-D Amphenol Advanced Sensors (Telaire) electronic component

T8200-D

SENSOR CARBON DIOXIDE 0-10V OUT

Amphenol Advanced Sensors (Telaire)

5
RFQ

Datasheet

T8000 Bulk Active Carbon Dioxide (CO2) - ±5% 0 V ~ 5 V, 0 V ~ 10 V (Selectable) 0°C ~ 50°C 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC 4 ~ 20mA
OXY-LC-A100-455 SST Sensing Ltd. electronic component

OXY-LC-A100-455

SENSOR OXYGEN 4MA-20MA OUTPUT

SST Sensing Ltd.

4
RFQ

Datasheet

- Bulk Active Oxygen (O2) 260 mbar ~ 1.26 bar ±0.5% 4mA ~ 20mA -30°C ~ 70°C 20V ~ 28V 600mA
110-801 SPEC Sensors (a division of Interlink Electronics) electronic component

110-801

SENSOR AIR QUALITY CURRENT OUT

SPEC Sensors (a division of Interlink Electronics)

39
RFQ

Datasheet

- Bulk Active Air Quality - - Current -10°C ~ 40°C - -
110-901 SPEC Sensors (a division of Interlink Electronics) electronic component

110-901

SENSOR AIR QUALITY CURRENT OUT

SPEC Sensors (a division of Interlink Electronics)

39
RFQ

Datasheet

- Tray Active Air Quality - - Current -10°C ~ 40°C - -
MICS-VZ-89TE 45 Amphenol Advanced Sensors (Telaire) electronic component

MICS-VZ-89TE 45

SENSOR AIR QUALITY I2C OUTPUT

Amphenol Advanced Sensors (Telaire)

28
RFQ

Datasheet

Telaire® Bulk Active Air Quality - - I2C, PWM 0°C ~ 50°C 3.135V ~ 3.465V -
MP7217DA Amphenol SGX Sensortech electronic component

MP7217DA

SENSOR FLAMMABLE GAS VOLTAGE OUT

Amphenol SGX Sensortech

80
RFQ

Datasheet

- Tray Active Flammable Gas - - Voltage -40°C ~ 60°C 2.9V ~ 3.1V 47mA
PS1-VOC-200 Amphenol SGX Sensortech electronic component

PS1-VOC-200

SENSOR VOC 200PPM

Amphenol SGX Sensortech

19
RFQ

Datasheet

PS1 Bulk Active Volatile Organic Compound (VOC) 800 mbar ~ 1.2 bar - - -40°C ~ 55°C - -
USEQGCCAC82N00 KEMET electronic component

USEQGCCAC82N00

SENSOR CARBON DIOXIDE VOLT OUT

KEMET

48
RFQ

Datasheet

QGC Tube Active Carbon Dioxide (CO2) - - Voltage -40°C ~ 85°C 2.7V ~ 8V -
968-008 SPEC Sensors (a division of Interlink Electronics) electronic component

968-008

SENSOR AIR QUALITY 0-3V OUTPUT

SPEC Sensors (a division of Interlink Electronics)

8
RFQ

Datasheet

- Bulk Active Air Quality - ±2% 0 V ~ 3 V -40°C ~ 50°C 2.7V ~ 3.3V 15µA
VQ548MP-DA Amphenol SGX Sensortech electronic component

VQ548MP-DA

SENSOR FLAMMABLE GAS VOLTAGE OUT

Amphenol SGX Sensortech

13
RFQ

Datasheet

VQ500 Bulk Active Flammable Gas - - Voltage -40°C ~ 60°C 2.9V ~ 3.1V 47mA
USEQGSM1N8L100 KEMET electronic component

USEQGSM1N8L100

SENSOR NITRIC OXIDE I2C OUTPUT

KEMET

2
RFQ

Datasheet

QGS Bulk Active Nitric Oxide (NO) - - I2C -40°C ~ 85°C 1.75V ~ 3.6V 23µA
PS1-H2S-100 Amphenol SGX Sensortech electronic component

PS1-H2S-100

SENSOR HYDROGEN SULFIDE

Amphenol SGX Sensortech

21
RFQ

Datasheet

PS1 Bulk Active Hydrogen Sulfide (H2S) 800 mbar ~ 1.2 bar - - -40°C ~ 55°C - -
PS1-HCHO-5 Amphenol SGX Sensortech electronic component

PS1-HCHO-5

SENSOR FORMALDEHYDE 5PPM

Amphenol SGX Sensortech

13
RFQ

Datasheet

PS1 Bulk Active Formaldehyde (HCHO) 800 mbar ~ 1.2 bar - - -20°C ~ 55°C - -
USEQGCCA50L100 KEMET electronic component

USEQGCCA50L100

SENSOR VOLTAGE OUTPUT TO39

KEMET

3
RFQ

Datasheet

QGC Tube Active - - - Voltage -40°C ~ 85°C 2.7V ~ 8V -
USEQGCDAC82100 KEMET electronic component

USEQGCDAC82100

SENSOR CARBON DIOXIDE VOLT OUT

KEMET

9
RFQ

Datasheet

QGC Tube Active Carbon Dioxide (CO2) - - Voltage -40°C ~ 85°C 2.7V ~ 8V -
USEQGCDAHC2100 KEMET electronic component

USEQGCDAHC2100

SENSOR HYDROCARBONS VOLTAGE OUT

KEMET

7
RFQ

Datasheet

QGC Tube Active Hydrocarbons - - Voltage -40°C ~ 85°C 2.7V ~ 8V -
Total 1306 Record«Prev1... 7891011121314...66Next»