Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR5211S-10SENSOR CURRENT MAGNETIC 10A DC |
0 |
|
Datasheet |
CR5200 | Module | Bulk | Obsolete | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 35mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220S-5SENSOR CURRENT MAGNETIC 5A DC |
0 |
|
Datasheet |
CR5200 | Module | Bulk | Obsolete | DC | Magnetic Modulator, Closed Loop | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 50mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220S-2SENSOR CURRENT MAGNETIC 2A DC |
0 |
|
Datasheet |
CR5200 | Module | Bulk | Obsolete | DC | Magnetic Modulator, Closed Loop | 2A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 50mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
LF 1005-S/SP52TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1005-S/SP36TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.55% | ±24V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP38TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1005-S/SP41TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP51TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP50TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP13TRANSDUCER |
0 |
|
- |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
ARU-B100-D300/SP4SENSOR |
0 |
|
Datasheet |
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | Voltage | 0.1mV/A | 346kHz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
AK 5 C420LTRANSDUCER |
0 |
|
Datasheet |
AK | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Current | - | 20Hz ~ 100Hz | - | ±1% | 24V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
CR4111S-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 0V ~ 10V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LV 100/SP67SENSORS |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 500-SFC/SP2TRANSDUCER |
0 |
|
Datasheet |
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP33TRANSDUCER |
0 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-S/SP15TRANSDUCER |
0 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.7% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LV 100/SP17SENSORS |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DHR 300 C5TRANSDUCER |
0 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
DHR 600 C10TRANSDUCER |
0 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 600A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.