Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AI-P1ATRANSDUCER |
0 |
|
Datasheet |
AI | Module | Bulk | Active | AC | Rogowski Coil | 5000A | 1 | Current | 22.5mV/kA | 10Hz ~ 1.5kHz | ±1% | ±0.5% | 16.8V ~ 31.2V | - | 350mA | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
CR4460-30SENSOR CURRENT XFMR 30A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-20SENSOR CURRENT XFMR 20A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-10SENSOR CURRENT XFMR 10A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-15SENSOR CURRENT XFMR 15A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-5SENSOR CURRENT XFMR 5A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-25SENSOR CURRENT XFMR 25A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LF 1005-S/SP13TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP1TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.6% | ±12V ~ 18V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4260-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4220S-100SENSOR CURRENT XFMR 100A AC |
0 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
ICD-A-300-CAN2-12CURRENT SENSOR - ISA-SCALE DC CO |
0 |
|
Datasheet |
ICD | Module | Tray | Active | DC | Shunt | 300A | 1 | - | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
CTSG0000SENSOR CURRENT SWITCH 250A AC |
0 |
|
Datasheet |
CTS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 250A | 1 | SSR | - | 6Hz ~ 100Hz | - | - | Self Powered | 120ms | 150mA | -50°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
SRCN-C290-410 CHANNELS AC CURRENT SENSOR RS |
0 |
|
- |
SRCN | Module | Bag | Active | AC/DC | Current Sensor | 50A | 10 | RS485 | - | - | - | ±2.5% | 23.5V ~ 24.5V | - | 60mA | 0°C ~ 65°C | - | - | Bidirectional | DIN Rail | - |
|
ENCORE (3A)TRANSDUCER CURRENT SENS SHUNT 3A |
0 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -25°C ~ 70°C | - | - | - | Free Hanging | - |
|
ARU-B100-D300/SP3SENSOR |
0 |
|
Datasheet |
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | Voltage | 0.1mV/A | 346kHz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
LTC 500-TTRANSDUCER |
0 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-STRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Current Transducer | 500A | 1 | - | - | DC ~ 150kHz | ±0.1% | ±0.6% | 15V ~ 24V | 1µs | 30mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-SFC/SP14TRANSDUCER |
0 |
|
- |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4420S-40SENSOR CURRENT XFMR 40A AC |
0 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.