Humidity, Moisture Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HS3004-ML1IC MODULE |
0 |
|
- |
HS300x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±3.5% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
|
HS3002-ML1IC MODULE |
0 |
|
- |
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HS3102-ML1IC MODULE |
0 |
|
- |
HS310x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±1.8% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
|
HS3104-ML1IC MODULE |
0 |
|
- |
HS310x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±3.5% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
|
HU-224-3-MAHumidity Sensor, Duct Mount, 3pc |
0 |
|
- |
HU-224 | - | Retail Package | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
OFT420-CSENSOR HUMI/TEMP ANALOG |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
|
OHT20-CSENSOR HUMI/TEMP USB |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Digital | - | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 5V | Cable | -25°C ~ 70°C | - | - | Radial |
|
OHT20-ASENSOR HUMI/TEMP USB |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Digital | - | ±1.5% RH | 3 s | 0.01°C, 0.01% RH | 5V | Cable | -25°C ~ 70°C | - | - | Radial |
|
OFT010-BSENSOR HUMI/TEMP ANALOG |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 10V | ±2% | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
|
OFT025-CSENSOR HUMI/TEMP ANALOG |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 2.5V | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
|
OFT005-CSENSOR HUMI/TEMP ANALOG |
0 |
|
Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 5V | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
|
26312factory calibrated |
6 |
|
- |
- | 4-SIP Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | - | - | ±5% RH | - | - | 3.5V ~ 5.5V | Through Hole | -40°C ~ 80°C | - | - | - |
|
NZH-101UHumidstat, Room, Internal Setpoi |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | SPDT | - | ±3% RH | 72 s | - | - | Chassis Mount | 0°C ~ 60°C | - | - | - |
|
A/RH5-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
|
A/RH5-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
|
A/RH5-AN-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
|
A/RH5-CP-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
|
A/RH5-AN-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
|
A/RH5-CP-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
|
A/RH5-DRelative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
Humidity, Moisture Sensors Electronic Components
Explore Humidity, Moisture Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.