Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CRD4170-15SENSOR CURRENT XFMR 15A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4170-25SENSOR CURRENT XFMR 25A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4170-5SENSOR CURRENT XFMR 5A AC |
0 |
|
Datasheet |
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LT 1005-T/SP39TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MGS-1800-15003PH 18" COILS 1500A:4-20MA |
1 |
|
Datasheet |
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 1500A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
LT 2005-TTRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | 0°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CD 100-S/SP8TRANSDUCER |
0 |
|
Datasheet |
CD | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Voltage | - | DC ~ 11Hz | - | ±3% | 15V | - | 60mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DV 4200/SP6TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 4000/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 2800/SP2TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 4200/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 3000/SP2TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ISOBLOCK I-ST-1C (50A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 50A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
HAZ 12000-SBTRANSDUCER |
0 |
|
Datasheet |
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 12000-SBITRANSDUCER |
0 |
|
Datasheet |
HAZ | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 12000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | 15V | 10µs | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 2005-S/SP24TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±12V ~ 15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP37TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP43TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP27TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP44TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.