Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR4180-50SENSOR CURRENT XFMR 50A AC |
0 |
|
Datasheet |
CR4100 | Module, Triple Pass Through | Bulk | Obsolete | AC | Transformer w/Conditioning | 50A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
20312009101SENSOR CURRENT HALL 2000A AC |
0 |
|
Datasheet |
HCMR | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±0.3% | 15V | 1µs | 33mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DK 100 B420 BTRANSDUCER |
0 |
|
- |
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | - | - | - | - | - | - | - | - | - | - | - | - | Chassis Mount | - |
|
DK 400 B420 BTRANSDUCER |
0 |
|
- |
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Current | - | DC | ±0.75% | ±2% | 20V ~ 50V | 100ms | 100mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP3TRANSDUCER |
0 |
|
- |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 1005-S/SP30TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 1005-S/SP28TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL0502SSENSOR CURRENT XFMR 10A, 20, 50A |
0 |
|
Datasheet |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A, 20, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP32TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL2002SSENSOR CURRENT 100A, 150A, 200A |
0 |
|
Datasheet |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
ISOBLOCK I-ST-1C (100MV 10V)TRANSDUCER CURRENT 9-28VDC |
0 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Obsolete | - | Current Transducer | - | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
|
1136504SENSOR CURRENT HALL 11A AC/DC |
0 |
|
Datasheet |
- | Module | Bulk | Active | AC/DC | Current Transducer | 1A, 5A, 10A (Selectable) | 1 | Analog Voltage | - | DC, 10Hz ~ 1kHz | - | - | 9.6V ~ 30V | 200ms | - | -40°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
LT 2005-S/SP3TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1100A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V | 1µs | - | -30°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD4550-XXX-MCRD4550-XXX-M |
0 |
|
Datasheet |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CRD4150-XX-MCRD4150-XX-M |
0 |
|
Datasheet |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 2005-S/SP12TRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.3% | ±15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 2005-S/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 2005-S/SP3TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP2TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP8TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.