| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAR 1000-STRANSDUCER |
0 |
|
- |
HAR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.5% | ±0.5% | 15V | 5µs | 20mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HAXC 1500-STRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CT 0.1-TPSENSOR CURRENT FLUX 100MA AC/DC |
0 |
|
- |
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 100mA | 1 | Ratiometric, Voltage | - | DC ~ 7kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.2-TPSENSOR CURRENT FLUX 200MA AC/DC |
0 |
|
- |
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.4-TPSENSOR CURRENT FLUX 400MA AC/DC |
0 |
|
- |
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 400mA | 1 | Ratiometric, Voltage | - | DC ~ 18kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAX 1500-S/SP20TRANSDUCER |
0 |
|
- |
HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SPA0TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SPA4TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP20TRANSDUCER |
0 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AP 400 B420LTRANSDUCER |
0 |
|
Datasheet |
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 100 B420LTRANSDUCER |
0 |
|
Datasheet |
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | - | Chassis Mount | - |
|
AP 200 B420LTRANSDUCER |
0 |
|
Datasheet |
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A, 150A, 200A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 50 B420LTRANSDUCER |
0 |
|
Datasheet |
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A, 25A, 50A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
ART-B22-D125/SP25CURR SENSE XFMR FLEXIBLE COIL |
0 |
|
Datasheet |
ART | Module | Bulk | Active | AC | Rogowski Coil | 2000A | 1 | Voltage | 0.0225mV/A | 420kHz | - | - | - | - | - | -40°C ~ 80°C | - | - | - | Chassis Mount | - |
|
HAL 750-S/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 210-S/SP5TRANSDUCER |
0 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Current | 1mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
20310500101SENSOR CURRENT HALL 500A AC |
1 |
|
Datasheet |
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.6% | 15V ~ 24V | 1µs | 24mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
|
20310200102SENSOR CURRENT HALL 200A AC |
0 |
|
Datasheet |
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 12V ~ 15V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
LA 305-S/SP5SENSORS |
0 |
|
- |
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.8% | ±12V ~ 15V | 500ns | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP16TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |