Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L31S400S05FSSENSOR CURRENT HALL 400A AC/DC |
0 |
|
Datasheet |
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WJCURRENT SENSOR (700A; 15V) |
0 |
|
Datasheet |
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WMCURRENT SENSOR (700A; 15V) |
0 |
|
Datasheet |
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
F01P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
Datasheet |
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±2.5% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
Datasheet |
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
Datasheet |
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P025S05SENSOR CURRENT FLUX GATE 25A AC |
0 |
|
Datasheet |
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CKSR 50-NP/SP1TRANSDUCER |
0 |
|
- |
CKSR | Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | 0.0125mV/A | DC ~ 300kHz | ±0.1% | ±1.2% | 4.75V ~ 5.25V | - | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S600D15WMSENSOR |
0 |
|
Datasheet |
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L31S500S05FSSENSOR CURRENT HALL 500A AC/DC |
0 |
|
Datasheet |
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L10P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
- |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
- |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
- |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P020D15SENSOR CURRENT HALL 20A DC |
0 |
|
- |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
- |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
Datasheet |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
Datasheet |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P010D15SENSOR CURRENT HALL 10A DC |
0 |
|
Datasheet |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
Datasheet |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
Datasheet |
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
Current Sensors Electronic Components
Explore Current Sensors electronic components, related subcategories, product specifications, datasheets and sourcing options. We support original component procurement, BOM sourcing and RFQ services for engineers, distributors and global buyers.